How To Repair Your Electro Air Air Cleaner

1. First remove BOTH collector cells from your Electro Air air cleaner.

2. Put the door back on, turn the air cleaner on and see if the light comes on for 30 seconds and then turns off. If it does you have an air flow sensor built into your air cleaner and that part is working.

3. Get the furnace blower running. You can do this by turning either the thermostat fan AUTO - ON switch to ON or turning the heat on and raising your thermostat set point.

IF THE INDICATOR LAMP DOES NOT COME ON

The problem is with the High Voltage Power Pack.
CLICK HERE TO HAVE US DIAGNOSE AND REPAIR THE PROBLEM

IF THE INDICATOR LAMP COMES ON & STAYS ON

The problem is with one OR both of your collector cells. If this is the case wash both of your collector cells, wait 48 hours and try it again with both collector cells. If it works now you are done.

IF THE LAMP GOES OUT WITH THE CELLS INSTALLED AFTER YOU HAVE CLEANED THEM AND WAITED 48 HOURS FOR THEM TO DRY

NOTE: For each retest you MUST turn off the blower, turn off the air cleaner for 1 minute, turn the air cleaner back on and wait another minute before turning on the furnace blower again.

1. Place a single cell all the way to the front of the air cleaner and retest. The cell must touch the back side of the door to make contact with the chrome piece in the center of the door. Turn on the air cleaner, wait 1 minute and then turn the blower back on.

2. Now remove that cell and try it with JUST the other cell placed all the way to the front of the air cleaner.

3. If the indicator lamp GOES OUT with one of the cells installed then that cell has a short in it.

4. Remove that faulty cell and carefully study it. Look for bent aluminum plates, broken ionizer wires or foreign objects stuck between any of the plates. Remove the foreign object, straighten the bent plate or replace the broken ionizer wire.

5. Retest that cell. If you see nothing wrong with it try shaking the cell. Sometimes a single plate will break loose from the cell. If you have a broken plate or find nothing wrong and it still shows a shorted cell, you need to replace that collector cell.

Below is a link to a diagnostic tree. Try it once you have exhausted the tests above.
To test if your Electro Air electronic air cleaner is working properly when you are done and the cells are installed, get the furnace blower running then slap the return (cold in winter) ductwork with the palm of your hand several times. This will loosen up some dirt in the ductwork. That dirt will enter the air cleaner and the air cleaner will temporarily begin making snapping noises. This is an indication it is working.

How to diagnose your Electro Air air cleaner.

OR - LET US DO IT

We will diagnose and repair your air cleaner for you for only $39.95. Click HERE to find out how.

 